Model
|
H-05
|
H-16
|
Sensor type
|
One K-type thermocourple
|
Two K-type thermocouples
|
Measuring range
|
-50℃
(-58℉) to 1300℃
(2000℉)
|
Resolution
|
1℃
(1℉) or 0.1℃
(0.1℉)
|
1℃
(1℉)
|
Accuracy
|
18℃
to 28℃ (64℉ to 82℉)
ambient
±(0.3%rdg+1℃ -500℃ to 1000℃ ±(0.5%rdg+1℃)
1000℃ to
1300℃
±(0.3%rdg+2℉)
-58℉ to 2000℉
|
Temperature
coefficient
|
0.1 times the applicable accuracy specifiction
per ℃
from 0℃
to 18℃
and 28℃ to
50℃ (32℉
to 64℉ and
82℉ to 122℉)
|
Reading rate
|
2.5 times per second
|
Working rage
|
0℃
to 50℃
(32℉
to 122℉)
|
Storage
temperature
|
-20℃
to 60℃
(-4℉
to 140℉)
|
Humidity range
|
0% to 80% (0℃
to 35℃)
(32℉
to 95℉)
0% to 70% (30℃
to 50℃) (95℉
to 122℉)
|
Power supply
|
Battery (9V) (NEDA 1604, IEC 6F22)
|
Battery life
|
200 Hours typical with carbon zine battery
|
Dimension
|
147mm (H)X70mm (W)X39mm (D)
|
Weight
|
7.4 oz (210g)
|
Input connection
|
Miniature connector for thermocouple
|
Accessories
|
9V battery, 4-foot type K thermocouple bead
probe
|